No. Efficiency is worst at very small loads, where the inverter’s own consumption is a large share of what it is delivering, and best somewhere below its maximum. A single headline efficiency figure describes one point on that curve.
Conversion efficiency is quoted as one number and behaves as a curve, and the shape of that curve decides an energy budget more than the peak does.
Why small loads are expensive
An inverter has consumption that does not depend on what it is delivering. Powering a small lamp, that fixed consumption can rival the lamp. As the load rises, it becomes a smaller share, which is why efficiency climbs steeply from near zero.
Why the maximum is not the best point
Losses that scale with current rise faster than the output at the top of the range, so the best efficiency sits somewhere below full output. A unit run permanently at its ceiling is neither at its most efficient nor at its coolest.
How to size against the curve
Match the inverter to the load that runs most of the time rather than to the largest load that ever runs. Where a large occasional load exists, a second small inverter for the steady loads is a common and unglamorous answer.
What to read on the datasheet
Peak efficiency, efficiency at a stated partial load if it is given, and idle consumption. Those three sketch the curve. A listing that gives only the first is giving the most flattering point on it.
Where this page and the manufacturer’s documentation differ, the documentation is the one to follow. Every capacity, output, input window, current limit, cycle count and temperature threshold on this page comes from the maker’s own published figures, with the unit as printed and the source named. None of it is measured here, and no figure is converted into another convention, because a converted number is a different number. And the distinction this page keeps: a nominal capacity is not the energy that reaches a socket. A reserve the chemistry never gives up, and the cost of converting stored direct current into a mains-style output, both sit between the two. Where a maker publishes a usable figure, this page reports it beside the nominal one; where only the nominal one exists, it says so rather than converting it.
What people ask before they order
Does that mean a bigger inverter is worse?
For a small load, generally yes: its fixed consumption is larger and the load sits further down the curve. Oversizing has a running cost that the headline figure hides.
Is a curve ever published?
Larger units sometimes publish efficiency at several load points, which is more useful than a peak figure. Where only one number exists, this site reports it as a peak rather than as an average.