Sun3drucker Single-phase 5(80) A, two-pole, DIN EN 50022 and DIN 43880
A single-phase two-pole DIN rail kWh meter rated 5(80) A with a backlit LCD, no reset function, and a reading retained through a power cut.
- Maximum current
- 5(80) A, from the title — a basic current of 5 A with a maximum of 80 A
- Direct or CT measurement
- Direct
- Phases
- Single phase, two poles, from the title
- Accuracy class
- Nowhere in the listing — high precision is claimed in the fifth bullet without a class
- Protocol
- Nowhere in the listing
- Width
- 17.5 mm pole width to DIN 43880, second bullet; 35 mm rail mounting to DIN EN 50022
- Reset behaviour
- No reset function at all, first bullet; the reading is retained in memory after a power cut. Working range −25 °C to 55 °C, up to 95 % relative humidity
- Amazon reference
- B083GYP8JS (same reference on 6 Amazon marketplaces)
- EAN
- 0795787227480
- Two dimensional standards cited — DIN EN 50022 for the rail and DIN 43880 for the module width
- The reading survives a power cut and cannot be reset, which is what a billing sub-meter needs
- No accuracy class
Best for: A sub-meter whose reading has to be trusted over years rather than watched daily.